Double-Head Three-Station Vertical Winding Machine

Short Description:

Solution: Reason 1. Insufficient negative pressure of the detection meter will lead to the failure to reach the set value and cause signal loss. Adjust the negative pressure setting to a suitable level.


Product Detail

Product Tags

Product Characteristics

● Double-head three-station vertical winding machine: two stations work and one station waiting; stable performance and atmospheric appearance. Fully open design concept, easy to debug.

● There is no obvious vibration and no obvious noise when running at high speed.

● The machine can arrange the coils neatly in the wire hanging cup, and simultaneously wind the main and auxiliary coils in the same wire cup fixture; automatic winding, automatic skipping, automatic processing of bridge wires, automatic cutting, automatic The indexing is completed at one time in sequence.

● The winding tension is adjustable, the bridge wire processing is fully servo controlled, and the length can be adjusted arbitrarily; it has the functions of continuous winding and discontinuous winding.

● Low energy consumption, high efficiency, low noise, long life and easy maintenance.

Vertical Winding Machine-3
Vertical Winding Machine-2

Product Parameter

Product number LRX2/3-100
Flying fork diameter 200-350mm
Number of working heads 2PCS
Operating station 3 stations
Adapt to the wire diameter 0.17-1.2mm
Magnet wire material Copper wire/aluminum wire/copper clad aluminum wire
Bridge line processing time 4S
Turntable conversion time 2S
Applicable motor pole number 2、4、6、8
Adapt to the stator stack thickness 15mm-100mm
Maximum stator inner diameter 100mm
Maximum speed 2600-3000 circles/minute
Air pressure 0.6-0.8MPA
Power supply 380V three-phase four-wire system 50/60Hz
Power 10kW
Weight 2000kg
Dimensions (L) 1860* (W) 1400* (H) 2150mm

FAQ

Problem : Diaphragm Diagnosis

Solution: Reason 1. Insufficient negative pressure of the detection meter will lead to the failure to reach the set value and cause signal loss. Adjust the negative pressure setting to a suitable level.

Cause 2. The diaphragm size may not match the diaphragm clamp, preventing proper operation. A matching diaphragm is recommended.

Reason 3. Air leakage in the vacuum test may be caused by improper placement of the diaphragm or fixture. Orient the diaphragm correctly, clean the clamps, and make sure everything fits correctly.

Reason 4. A clogged or faulty vacuum generator will reduce the suction and negatively affect the negative pressure value. Clean the generator to fix the problem.

Problem: When playing a movie with sound reversible, the cylinder only moves up and down.

Solution: When the sound film advances and retreats, the cylinder sensor detects a signal. Check sensor location and adjust if necessary. If the sensor is damaged, it should be replaced.

Problem: Difficulty in attaching diaphragm to fixture due to lack of suction from the vacuum.

Solution:

This issue could be caused by two possible reasons. Firstly, the negative pressure value on the vacuum detection meter may be set too low, causing the signal to be detected before the diaphragm is properly sucked in. To solve this issue, adjust the set value to a reasonable range. Secondly, the vacuum detection meter may be damaged, causing a constant signal output. In this case, check the meter for blockages or damages, and clean or replace it if necessary.


  • Previous: